Diamond Products CC7074 User Manual

Page 35

Advertising
background image

32

1. Pull out the tab on the air cleaner housing end

cover.

Figure 42: End Cover Tab


2. Turn the end cover counter-clockwise to unlock and

pull the cover away from the main air cleaner
housing.

3. Pull the outer primary filter out of the air cleaner and

inspect it for damages. Replace as necessary.

4. Move away from the saw and clean the filter from

the inside out. Use dry compressed air to clean the
filter (a maximum of 40 psi or 2.75 bar).

5. Inspect the inside of the air cleaner housing and the

end cover for debris, and wipe them down with a
damp cloth as necessary. DO NOT use compressed
air to blow out the inside of the air cleaner housing.
DO NOT allow dust to enter the air intake tube when
cleaning or replacing parts.

6. Place the filter into the air cleaner housing (over the

inner safety filter) and gently push the filter into the
unit until it feels secure.

Figure 43: Outer Primary Filter


7. Place the end cover tightly up against the ridge at

the end of the air cleaner housing.

8. Turn the end cover clockwise to lock the cover onto

the air cleaner housing, making sure the dust ejector
boot is in the vertical position.

9. Push the tab in on the air cleaner housing end cover

to secure.

Replacing the Inner Safety Filter
 DO NOT clean the inner safety filter.

 Replace it after approximately one year, or if there

are damages. DO NOT operate the saw without the
filter installed.


1. Pull the tab out on the air cleaner housing end

cover.

2. Turn the end cover counter-clockwise to unlock and

pull cover away from the air cleaner housing.

3. Pull the outer primary filter and the inner safety filter

out of the air cleaner housing. Inspect the outer
primary filter for damages and replace as necessary.

4. Inspect the inside of the air cleaner housing and the

end cover for debris, and wipe them down with a
damp cloth as necessary. DO NOT use compressed
air to blow out the inside of the air cleaner. DO NOT
allow dust to enter the air intake tube when cleaning
or replacing parts.

5. Insert a new inner safety filter into the air cleaner

housing and gently push the filter into the unit until it
feels secure.

Figure 44: Inner Safety Filter


6. Place the outer primary filter into the air cleaner

housing (over the inner safety filter) and gently push
the filter into the unit until it feels secure.

7. Place the end cover tightly up against the ridge at

the end of the air cleaner housing.

8. Turn the end cover clockwise to lock the cover onto

the air cleaner housing.

9. Push the tab in on the air cleaner housing end cover

to secure.

Advertising