MODEL 1601 FAN KIT

Installation

1601-093-B-5-11

DoorKing Part Number

1601-093

Copyright 2011 DoorKing, Inc. All rights reserved.

This kit is designed for the 1600 model barrier gate operators only. Recommended for hot and humid climates. An automatic
thermostat will control heat and humidity inside operator housing.

Kit Includes:

Fan Assembly with black and white wires, 5 wire ties,

3 double stick wire tie mounts, 2 plastic wire restrainers and 3 nylon
lock nuts.

Connect the fan power
wires according to
operator model type.

Mount fan using 3 existing
threaded studs and lock
nuts supplied. Slide
mounting tabs over
existing air duct.

Keep intake vents clear of debris.

Air

Flow

2

4

Fan switch settings.

OFF

- Turns the fan off.

ON

- Turns the fan on continuously.

AUTO

- Normal setting. Automatically turns the fan ON when the

temperature rises above 90°F inside the housing, and turns the fan OFF
when the temperature drops below 90°F.

5

Intake V

ents

Wire Stays

Exist

ing

Air Duct

Existing

Air Duct

Existing Wire Restrainers

Neutral

Neutral

Neutral

Mounting

Tab

Mounting

Tab

Hot

115 V

AC Hot

115 VAC Models

230 VAC/460 VAC Models

DANGER

HIGH VOLTAGE!

1

2

1

2

3

4

5

Exhaust V

ents

Lock Nut

Lock Nut

Lock

Nut

Threaded

Housing Studs

(Existing)

Threaded
Air Duct
Stud
(Existing)

Route fan wires as shown. Use supplied
wire stays and existing wire restrainers.
Keep wires clear of all moving parts.

3

3

1

2

120 Glasgow Avenue

Inglewood, California 90301

U.S.A.

4

Shut off ALL power to operator

Turn off the DC convenience open power switch
on certain operator models FIRST then shut off
the AC input power to the operator from the
circuit breaker.