Adjusting and locking cable assembly, Operator housing, Installing arms – DoorKing 1602 Barrier Gate User Manual

Page 9

Advertising
background image

1601-265-C-6-11

DoorKing Part Number

1601-310

Copyright 2011 DoorKing, Inc. All rights reserved.

Cable Eyelet MUST be installed in turnbuckle.

Cable Clamp

Important: Do not adjust cable too tight or it will bind.

Install eye bolt into arm
hinge with vise-grips.
Attach arm hinge to arm
with 4 self-tapping
screws.

1

2

3A

3A

Adjusting and Locking Cable Assembly

Existing Stud

After adjusting cable tension, lock turnbuckle
with nuts to keep turnbuckle from twisting.

Allow turnbuckle to
loosen or tighten.

Install arm on hub.

3

4

Install cable. Cable MUST clear hub!

Rotate arm up and down. Adjust cable tension with turnbuckle
to level outer arm. Make sure that cable assembly is not binding
or twisting and everything moves freely.

Cut off excess cable.

Top View of

Operator Housing

Side View of

Operator Housing

120 Glasgow Avenue

Inglewood, California 90301

U.S.A.

Hub

Remove stud from operator housing
and assemble as shown.

Lock eye bolt with nut to keep eye bolt from twisting.

Bushing

Operator Housing

Adjust to clear hub.

Pre-Crimped Eyelet

Inner Arm

Outer Arm

Bolt Head (Inside Housing)

Washer (Inside Housing)

Locknut

Install second arm
with 4 self-tapping
screws.

Installing Arms