RECOMMENDED TOOLS; Fig. 2

Fig. 2

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

Teflon Tape

Flat Blade Screwdriver

Adjustable Wrench

Tape Measure

Hacksaw

Tubing Cutter

File

For Sweat Connection; Solder and Torch

2.5mm Hex Wrench

1.5mm Hex Wrench

1

2

3

4

5

6

7

9

10

8

PRIOR TO INSTALLATION

Note: Prior to installing the Selectronic™Flush Valve
the following items must be installed.

1. Water Closet

2. Drain line

3. Water supply line

• Flush all water lines prior to operation (

See Step 4). Dirt

and debris can cause flush valve to run continuously.

• With the exception of Supply Stop Inlet, DO NOT use

pipe sealant or plumbing grease on any valve component

or coupling!

• Protect the chrome or special finish on the Flushometer.

DO NOT USE toothed tools on finished surfaces to install

or service these valves. Also see “Care and Cleaning”

section of this manual.

• This product contains mechanical and/or electrical

components that are subject to normal wear. These

components should be checked on a regular basis and

replaced as needed to maintain the valve’s performance.

IMPORTANT:
• All plumbing must be installed in accordance with
applicable codes and regulations.

• Water supply lines must be sized to provide an
adequate volume of water for each fixture.

2

Fig. 1

Roughing-in Dimensions

GENERAL DESCRIPTION:

Right or Left Hand Installation

10'

Exposed Flushometer

for 1-1/2" Top Spud Fixtures

SELECTRONIC™

PROXIMITY TOILET

FLUSH VALVE

Exclusive, self cleaning piston-type flush

valve with proximity operation and

manual override. Operates on DC

(batter y) power. Recommended

operating pressure 35 to 80 psi. Can

install left or right-handed. Detection

Zone can also be adjusted manually, or

with optional remote control.

See

(Section 5)

for converting Flush

Valve to Left Hand Installation.

M968699 Rev. 1.15

11-1/2"

(293mm)

16-1/8"

(409mm)

*-C-L-

6"

(152mm)

-C-L-

116mm

(4-5/8")

72mm

(2-7/8")

57mm

(2-1/4" MIN.)

DETECTION ZONE

400mm-800mm

(15-3/4" TO 31-1/2")

SUPPLY

DN 25mm

(1" I.P.S.)

15˚

FINISHED WALL

115mm-134mm

(4-1/2" TO 5-1/4")

FOR 1-1/2" TOP

SPUD FIXTURES

MANUAL

OVERRIDE

BUTTON

*CRITICAL

LEVEL

*Note: The Critical Line (-C-L-) on Vacuum
Breaker must typically be 6

"

(152mm) above

fixture. Consult Codes for details.