How to change the battery, Fig.12, How to retrofit our valve; fig. 10 – American Standard SELECTRONIC 6065.565 User Manual

Page 7: Fig. 11, Purchased before june 2013), Purchased after may 2013)

Advertising
background image

M968699 Rev. 1.15

Fig. 11b

3

HOW TO CHANGE THE BATTERY;

(purchased before June 2013)

Fig.12

6

3

3

9

1. Remove COVER (1) from SUPPLY STOP (2) if

installed.

Fig. 10.

2. Turn water supply off. Fig. 10.

3. Loosen SPUD COUPLING NUT (3). Unthread

COUPLING NUT

(4) and VACUUM BREAKER

COUPLING NUT

(5). Remove FLUSH VALVE (6).

Fig. 10.

4. Clean all threaded connections before installing the

new flush valve.

Fig. 10a.

5. Refer to Sections 5,6 and 7 to complete the retrofit

installation.

Fig. 10b.

Note: In most Retrofits the wall escutcheon, supply stop,
cover tube and vacuum breaker do not have to be replaced.
If these items do need replacement they must be purchased
separately or order the complete flush valve assembly from
American Standard.

HOW TO RETROFIT OUR VALVE;
Fig. 10

8

(Replaces Industry Standard Manual and

Electronic Valves)

CLEAN

CONNECTIONS

1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (2)

in back of top half of FLUSH VALVE CAP

(3). Fig. 11a.

2. Rotate CAP (3) to the right and pull off. Fig. 11b.

3. Turn CAP (3) over and disconnect the SENSOR (4)

from the BATTERY CABLE

(5). Remove the BATTERY

HOLDER

(6) with BATTERY (7). Fig. 11c.

4. Remove old BATTERY (7). Install the new BATTERY

(8) making sure the shape of the BATTERY (8) follows

the shape of the BATTERY HOLDER

(6). Fig. 11d.

5. Insert the BATTERY HOLDER (6) with BATTERY (8)

into FLUSH VALVE CAP

(3). Make sure the flat side of

the BATTERY HOLDER

(6) is facing towards the back

of the FLUSH VALVE CAP

(3). Reverse the above

steps to assemble flush valve.

Fig. 11d.

HOW TO CHANGE THE BATTERY;

(purchased after May 2013)

Fig. 11

1

10

10

7a

9

6

6a

Fig. 11a

Fig. 11

Fig. 12

REMOVE OLD

BATTERY

REMOVE OLD

BATTERY

INSTALL NEW

BATTERY

INSTALL NEW

BATTERY

2

4

6

6

5

CR

-P2

CR

-P2

8

7

Fig. 11c

Fig. 12a

Fig. 12b

9a

1. Remove CAP (3). Refer to Step 9 above. Fig. 11a.

2. Turn CAP (3) over and remove the two SCREWS

(9). Remove the BATTERY COVER (10) to expose the

battery

(6a). Fig. 12a.

3. Remove old BATTERY (6a). Install the new

BATTERY

(7a) making sure the + & - are facing up

towards the open end of the cover.

Fig. 12b.

4. Replace the BATTERY COVER (10) reverse the

above steps to assemble flush valve.

Fig. 11d

2

Fig. 10

Fig. 10a

Fig. 10b

1

4
5

3

6

Advertising