INSTALLATION

A ramp mount-weld on used with a formed angle application

is used when dock edge is damaged, there is no dock steel

securely anchored into the concrete, and the dock height is

too low and leveler must be installed above this height to

correct this situation.

Installation Steps:

1. Remove all existing bumper material and protruding

objects from dock edge. Clean and sweep dock

edge free of debris and flammable chemicals before

installing unit.

2. Review and follow formed angle installation instructions

prior to leveler installation. Reference page 18

3. At chosen location for Edge of Dock leveler, locate the

center of space and mark a point half of the base plate

width to the left and right.

4. At the points marked to each side of center, measure

and mark points 7-3/4” below dock level less height the

unit is to be raised to locate bottom of base plate. This

will locate the top of the base plate X” above dock level.

5. Using a proper lifting device, raise and position the

leveler base plate to marked position. While holding

base plate tight against dock face, tack weld securely

to dock steel on left hand end of leveler. Check right

hand end of base plate, ensure that end is against dock

steel and that the bottom of the base plate is even with

the marks made previously. Tack right hand end to

dock steel. Support unit until final welding is ready to

complete.

6. Position bump blocks out approximately 5/8” out from

the edge of the inside flange of the bump block to the

end of the base plate. Position the top of the tread

cover plate on the bump blocks to be flush with the top

of the base plate. Tack weld bump blocks to dock steel.

7. Place steel ramp plate in position, flush with top

backside of base plate. Mark along full length of back

edge of ramp plate. Slide ramp plate forward over dock

leveler the width of bushing tool, approximately, 2”.

8. Place bushing tool on marked line at each end of ramp

to ensure proper alignment at both ends, and tack weld

ramp plate to dock leveler to hold ramp plate in place

while bushing. A Skil Roto Hammer #736 or similar tool

is recommended.

9. Using the back edge of the ramp plate as a guide,

groove concrete approximately 3/4” deep by 2” wide,

and should be the entire length of ramp plate.

10. Break tack welds holding ramp in place, slide ramp

plate back into position with the top of the ramp plate

flush with the top of the base plate. Tack weld each end

and center of ramp plate to base plate.

11. Drill 5/8” dia. by 5” deep holes through ramp plate

at back edge. Install anchor bolts per manufacturers

specifications, and tighten securely. Weld anchor bolt

nuts to ramp plate using a 1/4” fillet weld all the way

around the nut. Cut off any portion of the anchor bolt

exposed through the nut, and plug weld around the top

of the nut to the anchor bolt. Ensure the top of the nuts

are well rounded for smooth rollover.

12. Complete welding of tacked parts as follows:

A. Apply continuous weld across top of each bumper

and base plate to ramp plate. Skip welding is

acceptable to prevent warping, but complete weld

must be completed.

B. Weld vertically along each end of base plate and

on both inboard and outboard flanges of bump

blocks.

C. Fully plug weld all holes in base plate.

13. Installer must remove all welding slag, and repaint

welded areas.

14. Installer must adjust main springs on all mechanical

Edge of Dock levelers to provide desired tension for

smooth operation. Stand on ground in front of leveler,

with the unit raised and secured in the maintenance

position, loosen jam nut on the underside of the linkage

pin. To start allow about 3/4” to 1” of threads between

top of jam nut and linkage pin. Using an open faced

wrench, hold locknut on inside of spring while tightening

threaded bolt until washer on top side sprint closes up

tight to jam nut. Test operation of unit. Further adjust

spring tension if needed by advancing jam nut toward

linkage pin and tightening threaded rod. After desired

unit operation is achieved, tighten jam nut to outer

washer on spring. Springs must be adjusted alternately

to have equal spring tension.

15. Before install is complete, installer must make a final

operational check of dock leveler to verify all phases

of install are correct. Installer must complete, sign,

and return the Installation Checklist upon completion.

Reference page 24.