ATON AH66T User Manual

Page 57

Advertising
background image

A T O N

AH66T

INSTALLATION MANUAL

©

ATON 2010 | All rights reserved.

Page 56

Primary Commands

Bass Level Control

Description: Adjusts Bass level in a zone. Status can be queried.

Examples:

&AH66,BAS,6,+<cr> INCREASES (+) the BASS (BAS)in ZONE SIX (6) by 1 dB.*
&AH66,BAS,9,-<cr> DECREASES (-) the BASS (BAS) in ZONE NINE (9) by 1 dB.*
&AH66,BAS,10,0<cr> Sets the BASS (BAS) in ZONE TEN (10) to FLAT (0).*
&AH66,BAS,2,+,6<cr> Sets the BASS (BAS) in ZONE TWO (2) to PLUS (+) SIX dB (6).
&AH66,BAS,3,-,2<cr> Sets the BASS (BAS) in ZONE THREE (3) to MINUS (-) TWO

dB (2).

&AH66,BAS,5,?<cr> QUERIES (?) the BASS (BAS) setting of ZONE FIVE (5).*
Example
QUERY responses are:*AH66,BAS,5,0 (ZONE FIVE-BASS is FLAT),

*AH66,BAS,2,+,3 (ZONE FIVE-BASS is PLUS 3),
*AH66,BAS,5,-,4 (ZONE FIVE-BASS is MINUS 4).

*When increasing or decreasing the BASS setting by 1 dB, setting BASS to 0 (flat), or

querying settings, Parameter 3 is not used.


DND (Do Not Disturb) Control

Description: Enables, Disables or TOGGLES the DND setting in a zone. Status can be
queried.

Examples:

&AH66,DND,6,0<cr>

Sets the DO-NOT-DISTURB (DND) setting in ZONE SIX (6) to OFF.

&AH66,DND,9,1<cr>

Sets the DO-NOT-DISTURB (DND) setting in ZONE NINE (9) to

ON.

&AH66,DND,10,2<cr> TOGGLES (2) the DO-NOT-DISTURB (DND) setting in ZONE TEN.

&AH66,DND,2,?<cr> QUERIES the DO-NOT-DISTURB (DND) setting in ZONE TWO.

Possible QUERY responses are:*AH66,DND,2,0, or*AH66,DND,2,1 where 0=OFF and

1=ON.

Prefix

Command

Parameter 1

Zone #

Parameter 2 Parameter 3*

+/- dBs

&AH66

BAS

1-12

+/-/0/?

1-12

Prefix

Command

Parameter 1

Zone #

Parameter 2

DND State

&AH66

DND

1-12

0/1/2/?