Operation – Victory UR-48-SBS User Manual

Page 10

Advertising
background image

SECTION 3
OPERATION

A.

Temperature Control

Temperature controls are factory set to maintain a food temperature of 38

°F (3.3°C) to 40°F (4.4°C) for

refrigerators and 0

°F (-17°C) to -5°F (-20.5°C) for freezers.

Temperature Control for Salad/Sandwich Units (

UR-27-SALA; UR-48-8A, 10A & 12A

)

The temperature control has two adjustments:

a. The “Cut in” temperature

b. The differential between “Cut in” and “Cut out” temperatures

The salad units have been adjusted to provide a “Cut in” temperature of 39

° F and a “Cut out”

temperature of 32

° F for the INLET AIR TO THE EVAPORATOR.

Fixed Timer to Guard Against “Freeze Ups”

The salad units use a fixed defrost timer to guard against “Freeze Ups”. Also the timer has a six (6) hour
cycle which includes twenty (20) minutes of “OFF” time. Observe the diagram and information below
for further assistance.

7

Section 3-Operation

Section 3-Operation

Advertising