3. Weekly Interior Surface Cleaning (continued)

f. Allow to air dry.

g. Return accessories to unit.

h. Return power (electric) to unit.

i. Return food to cabinet when temperature indicator reaches safety zone

.

4. Every Three Months, Condenser Maintenance

Cleaning is recommended at least once every three (3) months. However, once a month is
recommended when unit is located near cooking equipment which produces grease laden vapors,
i.e.: fryers, grills, steam kettles, etc.

a. Disconnect power by switching circuit breaker to “OFF” position or removing power cord

from receptacle

.

b. Use a vacuum cleaner with proper brush attachments to clean the condenser, compressor-

motor and related parts.

c. In extreme cases of dust and grease build-up, the condenser fins may require blowing out with

compressed air

.

Note:

The air cooled condensing unit depends upon the amount of air passing through the condenser.

Grease, lint and dust accumulation reduces required air flow. The refrigerator will consume less current
and operate more efficiently if the condenser is kept clean.

WARNING:

Failure to keep condenser clean may cause

premature failure of motor/compressor

which will NOT be covered by warranty!

D.

Lubrication

Unless otherwise specified, all Victory refrigerators are equipped with oilless type motors. The
compressor motor is a sealed unit and is constantly being lubricated when in operation. The condenser
and the evaporator motors are equipped with “Life-time” oiled bearings. These bearings are oiled at the
factory and need never be oiled again.

Section 4-Maintenance

Section 4-Maintenance

“End Of Section, Click Here For Table Of Contents”

Advertising