7.2.2 Real-time display indication mode.

While the mode is in real-time data indication ([D-NO] shows 0, 1 or 2. You can choose

the desired type of data by pressing the [

↓↓↓↓

] and [

↑↑↑↑

] keys to change the [D-NO] (data number).

The indicator will show the following data in "DATA" AND "ANGL.SPNO" for the selected
D-No..

Rotated angle.

Maximum torque (maximum hold).

2

Axis unit number

Torque voltage.

1

Axis unit number

Torque value.

0

ANGL.SPNO

DATA

D-No

PTorque value:

The real-time (current) torque value on the torque
transducer is shown.

PTorque voltage :

The real-time (current) torque signal voltage on the torque
transducer is shown.

PMaximum torque:

The peak torque, measured since the last resetting of the
switch within the current mode, is shown.

PAxis unit number:

The Axis unit No. as set up on the unit via dip switches

PRotated angle:

The real-time angle of rotation of the tool output shaft (in the
fastening direction CW), measured since the last resetting of

the switch within the current mode. (-119

°

to 999

°

).

Key operation during the real-time data indication mode.
Indication shown in "DATA"

D-NO

DATA

0

1

2

TORQUE VALUE

TORQUE VOLTAGE

PEAK TORQUE

(MAXIMUM HOLD)

OR

FIG. 7-2-2 Real time display selection