7.2.3 Fastening results display mode.

In fastening results display mode (when [D-NO] shows _0 ~

≡≡≡≡

4), data can be obtained by

pressing the [

↓↓↓↓

] and [

↑↑↑↑

] keys to scroll [D-NO] until the desired DATA item is displayed. The

following information will be displayed in the [DATA] and [ANGL/SPNO] display sections for
the displayed [D-NO]:

ANGLE @ PEAK TORQUE.

FINAL TORQUE.

≡≡≡≡

4

1ST PEAK ANGLE.

1ST PEAK TORQUE.

≡≡≡≡

3

1ST FINAL ANGLE.

1ST FINAL TORQUE

≡≡≡≡

2

2ND INCREMENT ANGLE.

2ND INCREMENT TORQUE.

≡≡≡≡

1

1ST INCREMENT ANGLE.

1ST INCREMENT TORQUE.

≡≡≡≡

0

5: ACCEPT.

4: REJECT.

3: STOP SIGNAL.

2: BYPASS SIGNAL.

1: ABNORMAL SIGNAL.

0: RESET / NO DATA / AFTER REVERSE.

SPINDLE NO

CAUSE OF FASTENING STOP:

=5

SPINDLE NO

REVERSE FLAG (ON: BACKED OUT, OFF: NOT BACKED
OUT)

=4

SPINDLE NO

SELF CHECK (ON: enabled, OFF: disabled)

=3

SPINDLE NO

NOT USED

=2

SPINDLE NO

FASTENING STEPS

=1

SPINDLE NO

FASTENING MODE.

====

0

SPINDLE NO

FASTENING MODE.

_7

SPINDLE NO

CYCLE TIME

_6

SPINDLE NO

FINAL STEP TIME.

_5

SPINDLE NO.

1ST STEP TIME.

_4

SPINDLE NO

2ND TORQUE RATE.

_3

SPINDLE NO.

1ST TORQUE RATE

_2

SPINDLE NO.

FINAL ANGLE

_1

FINAL ANGLE.

PEAK TORQUE.

_0

ANGL/SPNO

DATA

D-No

D-NO

DATA

PEAK TORQUE

FINAL ANGLE

OR

ANG/SPNO

_

_0

_1

_2

_3

1ST TORQUE RATE

2ND TORQUE RATE

(DISPLAY [D-No]

DATA DISPLAYED

FIG. 7-2-3 Fastening results display selection