4.4 Voltage Measurement

CAUTION: Maximum Input Voltage is 600Vrms, do not

exceed this rating to avoid personal injuries

or damage to the instrument.

4.5.2 Continuity Test
Set the function selector knob to

(Resistance). Insert the red test lead

into the positive input terminal (+), and the black test lead into the COM

terminal on the front of the instrument. Proceed to connect the test leads

tips across the component or circuit under test. If the resistance less is

than 100,, the buzzer will emit a continuous tone.

4.6 Other Functions

4.6.1 Relative Measurements
By pressing the ZERO button, the instrument is entered into zero mode

and the indicator will appear on the LCD screen. The value in the

display immediately before pressing the button is stored into memory as

a reference value for future tests. To exit the Zero mode press the ZERO

button again.

4.6.2 Data Hold and Peak Hold
Pressing the HOLD/PEAK button once, the present reading is held and

appears on the display. Press the switch again to return to normal mode

(continuous readings) and to release the data hold feature. The PEAK

HOLD function is enabled by pressing the HOLD/PEAK button until the

indicator appears on the screen. When in this mode, the instrument will

hold and display the highest reading obtained during the measurement.

To exit the peak/hold mode press the HOLD button for approx. 2 sec. until

the display indicator turns off. This function works with DCV, ACV, DCA

and ACA.
4.6.3 Auto Power Off
The meter will turn off automatically after approximately 30 minutes of no

operation to extend the battery life. Auto power off can be disabled by

pressing and holding down the ZERO button while turning on the instru-

ment, when auto power is off, the symbol on the screen will not appear.

Auto power off will be re-enable after turning off and on the instrument.

5. MAINTENANCE

CAUTION: Before attempting battery removal or replace-

ment, disconnect test leads and remove the

instrument from any energized circuit to

avoid shock hazard.

5.1 Battery Replacement
When the battery needs replacement, the battery symbol

will be ap-

pear in the upper left hand side of the LCD display. To replace the battery,

remove the screws at the back cover and replace with a 2 AAA 1.5 V

alkaline batteries.

5.2 Cleaning
Periodically wipe the case with a soft damp cloth and mild household

cleanser. Do not use abrasives or solvents. Ensure that no water gets

inside the instrument to prevent possible shorts and damage.

6. WARRANTY

One year limited warranty, excluding batteries and fuses. For details
see Standard Warranty Information in our webpage or you may request
a printed copy.

4.4.1 DC Voltage Measurement
Set the function selector knob to (DCV). Insert the red test lead into the

positive input terminal (+), and the black test lead into the COM terminal

on the front of the instrument. Proceed to connect the test leads across

the source or load under measurement. The polarity will be indicated when

the tip probe is connected. Read voltage in the display.
4.4.2 AC Voltage Measurement
Set the function selector knob to (ACV). Insert the red test lead into the

positive input terminal (+), and the black test lead into the COM terminal

on the front of the instrument. Proceed to connect the test leads across the

source or load under measurement. Read voltage in the LCD screen.

4.5 Resistance and Continuity Measurement

CAUTION: Maximum Input Voltage is 600Vrms, do not

exceed this rating to avoid personal injuries

or damages to the instrument. Also ensure

there is no power applied to the circuit and

that all capacitors are discharged.

4.5.1 Resistance Measurement
Set the function selector knob to

(Resistance). Insert the red test lead

into the positive input terminal (+), and the black test lead into the COM

terminal on the front of the instrument. Proceed to connect the test leads

across the component or circuit under test. Read resistance in Ohms on

the LCD screen.

600V CATII

300V CATIII 600A

H

HOLD

OFF

A

A

V

V

ZERO

P H

600V CATII

300V CATIII

600V

���

P

PEAK

Press

2 Sec

600V CATII

300V CATIII 600A

H

HOLD

OFF

A

A

V

V

ZERO

P H

600V CATII

300V CATIII

600V

���

P

PEAK

Press

2 Sec

Battery

© Copyright 2010 General Technologies

General Technologies Corp.

#121 - 7350 72nd Street Tel.: (604) 952-6699

Delta, BC

Fax: (604) 952-6690

Canada V4G 1H9

www.generaltechnologies.net

Advertising