3.1 Instrument Description

1) Capacitive pickup

2) Flexible probe

3) Protective rubber holster

4) LCD Display

5) Power ON/OFF / Reset button

6) Cylinders Increase button

7) Engine Cycles / KV Adjust select button

8) Cylinders Decrease button

9) Function select button

MIN - Minimum reading

• Hold and displays the minimum value of the measurements, with the last digit rounded

to ‘0’. The minimum value is automatically reset when turning the unit off or manually

by momentarily pressing the ‘Power On/Off / Reset’ button.

Spark Detected

• A flashing high voltage symbol ‘

‘ indicates that sparks are being detected in the ignition

system.

Number of Cycles

• Displays the selected number of cycles: 2, 4 or DIS (Distributor-less or waste spark

ignition system)

Number of Cylinders

• Displays the selected number of cylinders: 1, 2, 3, 4, 5, 6, 8, 10 and 12

Function with measurement units

• The selected function with the measurement unit are displayed as follows:

Display

Function

Measurement units

RPM

Tachometer

RPM (Revolutions per minute)

Peak KVolt

Spark plug wire peak voltage

KVolt ( 1000 x Volt)

Measurement reading

• Displays the measurement of the selected function.

3.3 Buttons description and operation

3.3.1 Power ON/OFF and Reset

• When the instrument is OFF, to turn it ON press the ‘Power ON/OFF / Reset’

button until the unit turns on (in approximately 1 second).

• When the instrument is ON, to turn it OFF press and hold the ‘Power ON/OFF

/ Reset’ button until the display turns off (in approximately 3 seconds).

• When the instrument is ON, press momentarily the ‘Power ON/OFF / Reset’

button to reset the maximum and minimum values.

Note: To extend battery life, the TA100 will automatically turn off after 1 minute of being

idle (i.e. no button pressed and no input signal). Turning the unit off manually,

when not in use will prolong battery life.

3.3.2 Number of cycles / KV Adjust

• Press the ‘Engine Cycles / KV Adjust’ button to select the number of cycles for

the engine under measurement. Each time the button is pressed the number

of cycles will change between 2 cycles, 4 cycles, and DIS settings. The

selected setting will show on the display.

• Press and hold the ‘Engine Cycles / KV Adjust’ button for a few seconds to

switch the instrument to KV Adjust mode.

3.3.3 Function Select

• Press the ‘Function Select’ button to select the measurement function. Each

time the button is pressed the measurement function will change between RPM

(Tachometer) and Peak KVolt (Spark plug wire peak voltage). The selected

setting will be shown on the display.

3.2 LCD Display

3.2.1 LCD Display description

Low battery indicator

• This message warns the battery voltage is below the minimum recommended and it

needs to be replaced with a new battery.

• If the battery voltage is low, but still allows for the operation of the instrument, the low

battery indicator will turn and stay on until the battery is replaced with a new one.

Note: If the unit turns off immediately after being turned on, it indicates the battery

voltage is below the absolute minimum, and the battery should be replaced to prevent

malfunction.

MAX - Maximum reading

• Hold and displays the maximum value of the measurements, with the last digit rounded to ‘0’.

The maximum measurement is automatically reset when turning the unit off or manually by

momentarily pressing the ‘Power On/Off / Reset’ button.

Fig. 1 - Instrument description

1

2

3

4

5

6

7

8

9

MAX

MIN

Cycles

Peak

Cylinders

Fig. 2 - LCD Display

MAX

MIN

Cycles

Peak

Cylinders

Number of cylinders
Maximum reading
Minimum reading

Function with

measurement units

Number of cycles

Low battery indicator

Spark detected

Measurement reading