REASSEMBLY

All procedures for reassembling the pump are the reverse of the previous instructions

with further instructions as shown:
1. The diaphragm assemblies are to be installed with the natural bulge outward

or toward the head of the center screw. Make sure both plates are installed with

outer radii against the diaphragm. After all components are in position in a vise and

hand tight, set a torque wrench for 480 inch pounds (40 ft. pounds) (54.23 Newton

meters) or, 600 inch pounds (50 ft. pounds) (67.79 Newton meters) for Santoprene,

using a (3/8") allen head socket. After each diaphragm sub assembly has been

completed, thread one assembly into the shaft (held near the middle in a vise having

soft jaws to protect the finish) making sure the stainless steel washer is in place on the

capscrew.

Make sure 1/4"-20 mounting screw has been removed and that the bumper (Item

#19 on drawing) is in place in the shaft.

Install this sub assembly into the pump and secure by placing the outer chamber

housing and capscrews on the end with the diaphragm. This will hold the assembly

in place while the opposite side is installed. Make sure the last diaphragm assembly

is torqued to 30 ft. lbs. (40.67 Newton meters) before placing the outer diaphragm

over the capscrews. If the holes in the diaphragm flange do not line up with the holes

in the chamber flange, turn the diaphragm assembly in the direction of tightening

to align the holes so that the capscrews can be inserted. This final torquing of the

last diaphragm assembly will lock the two diaphragm assemblies together. Place

remaining outer chamber on the open end and tighten down the securing nuts

gradually and evenly on both sides.

Caution should be used while reassembling Flap valves. The valves are designed

for some preload over the retainer hinge pad. This is done to insure proper face contact

with the seat. After all parts are in place, tighten the lock nuts down on the assembly

to the point where visual inspection shows that seat and valve face mate without gap.

This is important for dry prime. However, after priming action has started, valves will

function due to differential pressure without concern or trouble.

PILOT VALVE

The pilot valve assembly is accessed by removing the main air distribution valve

body from the pump and lifting the pilot valve body out of the intermediate housing.

Most problems with the pilot valve can be corrected by replacing the o-rings. Always

grease the spool prior to inserting it into the sleeve. If the sleeve is removed from the

body, reinsertion must be at the chamfered side. Grease the o-rings to slide the sleeve

into the valve body. Securely insert the retaining ring around the sleeve. When reinserting

the pilot valve, push both plungers (located inside the intermediate bracket) out of the

path of the pilot valve spool ends to avoid damage.

PILOT VALVE ACTUATOR

Bushings for the pilot valve actuators are threaded into the intermediate bracket

from the outside. The plunger may be removed for inspection or replacement. First

remove the air distribution valve body and the pilot valve body from the pump. The

plungers can be located by looking into the intermediate. It may be necessary to

use a fine piece of wire to pull them out. The bushing can be turned out through the

inner chamber by removing the outer chamber assembly. Replace the bushings if pins

have bent.