Warranty, Troubleshooting – Blagdon Pump X75 Aluminium User Manual

Page 11

Advertising
background image

x75afvmdl7sm-rev0411

Page 9

WARRANTY:

This unit is guaranteed for a period of five years against defective material and workmanship.

POSSIBLE CAUSES:

A.

Air leak in suction line.

B.

Excessive suction lift.

C.

Flap valve not seating properly.

D.

Leakage at joint of suction manifold or elbow flange.

E.

Suction line or strainer plugged.

F.

Diaphragm ruptured.

POSSIBLE CAUSES:

A.

Discharge hose or line plugged, or discharge head requirement

greater than air supply pressure.

(Disconnect discharge line to check.)

B.

Spool in air distribution valve not shifting.

(Remove end cap and check spool — must slide freely.)

C.

Diaphragm ruptured.

(Air will escape out discharge line in this case.)

D.

Blockage in diaphragm chamber preventing movement.

(Shut off air supply and reopen after pressure is relieved.)

POSSIBLE CAUSES:

A.

Flap valve not sealing properly in one chamber.

B.

Diaphragm failure in one chamber.

C.

Air leak at suction manifold joint or elbow flange one side.

PROBLEM

Pump cycles but will not pump.

(Note: higher suction lifts require faster

cycling speed for priming.)

PROBLEM

Pump will not cycle. (Note: Always

disconnect air supply to relieve air

pressure before disassembling any

portion of pump.)

PROBLEM

Uneven discharge flow. (Indicates one

chamber not operating properly.)

TROUBLESHOOTING

Advertising
This manual is related to the following products: