Air exhaust, Between uses, Flap valve servicing – Blagdon Pump X75 Aluminium User Manual

Page 9: Diaphragm servicing

Advertising
background image

x75afvmdl7sm-rev0411

Page 7

that the bumper stays in place allowing the sleeve to press in all the way. Reinstall the

spool, opposite end cap, gasket and bumper on the valve body. After inspecting and

cleaning the gasket surfaces on the valve body and intermediate, reinstall the valve

body on the pump using new gaskets. Tighten the four hex head capscrews evenly and

in an alternating cross pattern.

AIR EXHAUST

If a diaphragm fails, the pumped liquid or fumes can enter the air end of the pump,

and be exhausted into the atmosphere. When pumping hazardous or toxic materials,

pipe the exhaust to an appropriate area for safe disposition.

This pump can be submerged if materials of construction are compatible with the

liquid. The air exhaust must be piped above the liquid level. Piping used for the air

exhaust must not be smaller than 1" (2.54 cm). Reducing the pipe size will restrict air

flow and reduce pump performance .When the product source is at a higher level than

the pump (flooded suction), pipe the exhaust higher than the product source to prevent

siphoning spills.

Freezing or icing-up of the air exhaust can occur under certain temperature and

humidity conditions. Use of an air dryer unit should eliminate most icing problems.

BETWEEN USES

When used for materials that tend to settle out or transform to solid form, the pump

should be completely flushed after each use, to prevent damage. Product remaining

in the pump between uses could dry out or settle out. This could cause problems with

valves and diaphragms at re-start. In freezing temperatures, the pump must be drained

between uses in all cases.

FLAP VALVE SERVICING

Valve inspection requires removal of 3/8" hex nuts and elbows. When the top suction elbows

are removed, the valve and seat are connected as an assembly. When the bottom discharge

elbows are removed, the valve and seat stay with the outer chamber. Visual inspection and

cleaning is possible. If parts are to be replaced, remove the self-locking nuts and all parts

are accessible.

DIAPHRAGM SERVICING

Diaphragms can be inspected or the diaphragm assembly removed without

removing the suction and discharge flanges. Remove (8) nuts around the chamber

flange, and the housing assembly will pull off. Flap valves can be inspected for

proper seating at this point as well as the diaphragm. Use care to keep foreign

matter from behind the diaphragm. The opposite diaphragm may be inspected by the

same procedure. If either diaphragm has to be replaced, follow closely these steps:

Pull the outer diameter of one diaphragm off the (8) capscrews. NOTE: One

side only! On the free diaphragm assembly, use a 3/8" allen wrench to turn the

assembly (diaphragm, plates and screw) loose from the shaft. Once the assembly

has turned, it will turn out by hand by use of the diaphragm. Now the opposite

diaphragm assembly and the drive shaft will pull free from the capscrews and pump

intermediate assembly. The interior components consisting of sleeve bearings, rod

seals, and pilot valve actuator bushings are now accessible for service if required.

Hold the shaft in a clamping device making sure to protect surface of shaft so as not to

scratch or mar it in any way. The diaphragm assembly will turn loose. To disassemble

the components, turn a 1/4"-20 capscrew by hand into the tapped hole in the inner

plate. This keeps the plate from turning while the socket head capscrew is removed. To

do this, place assembly in a vise so the two protruding ends of screws are loose in the

vise jaws (about 3/4" apart). Turn the center screw loose from the back plate and the

assembly will come apart.