x75afvmdl7sm-rev0411

Page 1

X75 Aluminium Flap Valve Pump
Design Level 7

Air-Operated

Double Diaphragm Pump

ENGINEERING, PERFORMANCE

& CONSTRUCTION DATA

SUCTION/DISCHARGE PIPE SIZE

3" 150# ANSI Flange

CAPACITY

(0 to 988 liters per minute)

AIR VALVE

No-lube, no-stall

design

SOLIDS-HANDLING

Up to nearly 3" (75mm)

HEADS UP TO

125 psi or 289 ft. of water

(8.8 Kg/cm

2

or 88 meters)

Pumps are designed to be powered only by compressed air.

II 2GD T5

See page 17

for ATEX ratings

10

0

20

30

40

50

60

70

80

90

20

0

40

60

80

100 120 140 160 180 200 220 240 260

20(34) 40(68)

60(101.9)

80(135.9)

100(169.9)

100 PSI

80 PSI

60 PSI

40 PSI

20 PSI Air Inlet Pressure

100

Liters per minute

U.S. Gallons per minute

CAPACITY

0

100

200

300

400

500

600

700

800

900

1000

AIR CONSUMPTION

SCFM (M

3

/hr)

BAR

HEAD

0

1

2

3

4

5

6

7

PSI

120(203.9)

MODEL HDF3-A Performance Curve

Performance based on the following: elastomer fitted pump, flooded suction,

water at ambient conditions. The use of other materials and varying hydraulic

conditions may result in deviations in excess of 5%.

Advertising