Preparation

Employees authorized to perform lockout shall ensure that the appropriate energy isolating device (i.e., circuit

breaker, fuse, disconnect, etc.) is identified for the lift being locked out. Other such devices for other equipment

may be located in close proximity of the appropriate energy isolating device. If the identity of the device is in

question, see the shop supervisor for resolution. Assure that proper authorization is received prior to performing

the lockout procedure.

Sequence of Lockout Procedure

1)

Notify all affected employees that a lockout is being performed and the reason for it.

2)

Unload the subject lift. Shut it down and assure the disconnect switch is “OFF” if one is provided on the

lift.

3)

The authorized lockout person operates the main energy isolation device removing power to the subject

lift.

If this is a lockable device, the authorized lockout person places the assigned padlock on the device to

prevent its unintentional reactivation. An appropriate tag is applied stating the person’s name, at least 3”

x 6” in size, an easily noticeably color, and states not to operate device or remove tag.

If this device is a non-lockable circuit breaker or fuse, replace with a “dummy” device and tag it appro

priately as mentioned above.

4)

Attempt to operate lift to assure the lockout is working. Be sure to return any switches to the “OFF” posi

tion.

5)

The equipment is now locked out and ready for the required maintenance or service.

Restoring Equipment to Service

1)

Assure the work on the lift is complete and the area is clear of tools, vehicles, and personnel.

2)

At this point, the authorized person can remove the lock (or dummy circuit breaker or fuse) & tag and

activate the energy isolating device so that the lift may again be placed into operation.

Rules for Using Lockout Procedure

Use the Lockout Procedure whenever the lift is being repaired or serviced, waiting for repair when current

operation could cause possible injury to personnel, or for any other situation when unintentional operation could

injure personnel. No attempt shall be made to operate the lift when the energy isolating device is locked out.

Operating Conditions

Lift is not intended for outdoor use and has an operating ambient temperature range

of 41º-104ºF (5º-40ºC).

IMPORTANT SAFETY INSTRUCTIONS

When using your garage equipment, basic safety precautions should always be followed, including the follow-

ing:

1.

Read all instructions

2.

Care must be taken as burns can occur from touching hot parts.

3.

Do not operate equipment with a damaged cord or if the equipment has been dropped or damaged - until

it has been examined by a qualified service person.

Advertising