Direct Lift PP8 Plus Long User Manual

Page 15

Advertising
background image

15

PREVENTIVE MAINTENANCE SCHEDULE

The periodic Preventive Maintenance Schedule given is the suggested minimum requirements and minimum

intervals; accumulated hours or monthly period, which ever comes sooner.

Periodic maintenance is to be performed on a daily, weekly, and yearly basis as given in the following para-

graphs.

In the event you need replacement parts, use only Direct Lift replacement parts available from your local Direct

Lift distributor.

Do not modify the lift in any manner without the prior written consent of the manufacturer.

WARNING!

Occupational Safety and Health Administration (OSHA) and the American National Standards Institute (ANSI)

requires users to inspect lifting equipment at the start of every shift. These and other periodic inspections are

the responsibility of the user.

Failure to perform the daily pre-operational check can result in expensive property damage, lost production time,

serious personal injury, and even death. The safety latch system must be checked and working properly before

the lift is put to use.

Failure to heed this warning can result in death or serious injury, or damage to equipment. If you hear a noise not

associated with normal lift operation, or, if there is any indications of impending lift failure - CEASE OPERATION

IMMEDIATELY! - Inspect, correct and/or replace parts as required. Use only Direct Lift replacement parts avail-

able from your local Direct Lift distributor.

Daily Pre-Operation Check (8-Hours)

Check safety lock audibly and visually while in operation

Check safety latches for free movement and full engagement with rack.

Check hydraulic connections, and hoses for leakage.

Check cables connections bends, cracks-and for loose fittings.

Check for frayed cables in both raised and lowered position.

Check snap rings at all rollers and sheaves.

Check bolts, nuts, and screws and tighten if needed.

Check wiring & switches for damage.

Check floor for stress cracks near columns.

Check Lubrications on cable sheaves and shafts.

Weekly Maintenance (every 40-Hours)

IF LIFT IS ANCHORED TO FLOOR - Check anchor bolts torque to 50 ft-lbs for the ¾ in. anchor bolts. Do not

use an impact wrench to tighten anchor bolts.

Check floor for stress cracks near columns

Check hydraulic oil level.

Check and tighten bolts, nuts, and screws.