Fairbanks OMEGA SERIES COUNTING SCALE User Manual
Page 40

Section 5: Programming Configuration
04/13
40
51278 Rev. 2
4. Serial 1 - Parity continued,
Display
Descriptions
SEr.1
PArit
8-E-1
Sets the parity to 8-E-1
SEr.1
PArit
8-o-1
Sets the parity to 8-o-1
SEr.1
PArit
7-o-2
Sets the parity to 7-o-2
Example:
To print net weight only:
1. Open a hyper terminal session and set connection as 9600 8-n-1.
2. Set Serial 1 as PrESS, weight output as print net, baud rate as 9600 and
parity as 8-n-1, and others parameters are set to No.
3. After the scale boot, press the
key. Data on Hyper terminal will show:
0.0000 lb NT
4. Cycle power to the scale and change serial 1 settings to Auto. Change the
weight output to print Gross, Tare and Net. Change the baud rate to 19200
and parity as 7-n-2 , and all others parameters are set to No.
5. Close hyper terminal and modify its connection as 19200 7-n-2.
6. After the scale reboot, put 1 pound item on scale pan.
7. The scale will output data when the weight is stable. The Data output will be
as show below:
1.0000 lb GR
0.0000 lb TA
1.0000 lb NT