Section 5: Programming Configuration
04/13
43
51278 Rev. 2
12. Serial 1 - Accumulation Weight Information Print
Display
Descriptions
SEr.1
ACC.LUGt
no
Data prints without the total accumulated weight. (Default)
SEr.1
ACC.LUGt
YES
Data prints with the total accumulated weight.
Example 1:
1. Open a hyper terminal session and connect at 9600 8-n-1.
2. Set Serial 1 to PrESS, weight output using print net. Set the baud rate to
9600, 8 characters, No parity, and 1 stop bit.
3. Set PLU = YES, Time and date = no, Piece information = YES, Piece
Weight = no, Accumulation information = YES, and Accumulation Weight
= no.
4. Press
to set Piece Weight as 0.001 lb.
5. Press
to store current data in PLU 1.
6. Put 1 pound item on scale weighing pan.
7. Press
to record 1 Accumulation data.
8. Press the
key. The data output is shown below:
1.0000 lb NT
PLU 1
1000 PCS
1 ACC#