Fairbanks OMEGA SERIES COUNTING SCALE User Manual
Page 49

Section 5: Programming Configuration
04/13
49
51278 Rev. 2
D. Zero range
Display
Descriptions
rAnGE 2
Scale zero range. If the weight is higher than 2% of the scale’s
capacity, the scale cannot be zeroed.
rAnGE 100
Scale zero range. If the weight is higher than 100% of the
scale’s capacity, the scale cannot be zeroed.
Note:
The Zero rAnGE setting cannot make the scale exceed its rated capacity. For
example, if a 6 lb scale zeroes off a 3 lb weight, the amount of weight applied to the
scale cannot exceed 3 lb before the scale reaches its maximum rated capacity.
Example:
1. Set Zero range as 2.
2. Place a 1 pounds item on scale weighing pan.
3. Press
key to set current weight to zero. The scale will emit an error beep
(long beep) and show Error on the display.
4. Cycle power to the scale and enter the rAnGE setting menu.
5. Set Zero range to 100.
6. Press
key to set current weight to zero. Scale will set the current weight to
zero. The weight display should indicate 0.