D. Zero range

Display

Descriptions

rAnGE 2

Scale zero range. If the weight is higher than 2% of the scale’s
capacity, the scale cannot be zeroed.

rAnGE 100

Scale zero range. If the weight is higher than 100% of the
scale’s capacity, the scale cannot be zeroed.

Note:

The Zero rAnGE setting cannot make the scale exceed its rated capacity. For
example, if a 6 lb scale zeroes off a 3 lb weight, the amount of weight applied to the
scale cannot exceed 3 lb before the scale reaches its maximum rated capacity.

Example:

1. Set Zero range as 2.

2. Place a 1 pounds item on scale weighing pan.

3. Press

key to set current weight to zero. The scale will emit an error beep

(long beep) and show Error on the display.

4. Cycle power to the scale and enter the rAnGE setting menu.

5. Set Zero range to 100.

6. Press

key to set current weight to zero. Scale will set the current weight to

zero. The weight display should indicate 0.