51278 Rev. 2
B. Zero tracking
Sets the zero tracking by number of divisions.
Display
Descriptions
trAcE no
Zero tracking disabled.
trAcE 0.5d
Zero tracking enabled, tracking set to 0.5d
trAcE 1d
Zero tracking enabled, tracking set to 1d. (Default)
trAcE 2d
Zero tracking enabled, tracking set to 2d
trAcE 3d
Zero tracking enabled, tracking set to 3d
C. Display Tolerance
Sets the display tolerance or motion detection value.
Display
Descriptions
no.dEt no
Display tolerance is disabled.
no.dEt 0.5d
Display tolerance is 0.5d. If the weight changes are under
0.5d, the display will not update and motion is not indicated.
no.dEt 1d
Display tolerance is 1d. If the weight changes are under 1d,
the display will not update and motion is not indicated.
no.dEt 2d
Display tolerance is 2d. If the weight changes are under 2d,
the display will not update and motion is not indicated.
no.dEt 3d
Display tolerance is 3d. If the weight changes are under 3d,
the display will not update and motion is not indicated.