The following example shows the units portion of a serial stream format where the units field
begins at position 12 and is a character string of length 2 The pound value is "lb" and the kilogram
value is "kg". There is no units mask.


....... 12,c,2,lb,kg,, ......

The following example shows the units portion of a serial stream format where the units field
begins at position 12 and is a one character status. The fourth bit from the left in the status
character is zero for pounds and one for kilograms. (The mask for bit four is ansi code 8.) The
values given for pounds and kilograms reflect the value of the status character after the mask has
been applied.


...... 12,s,1,0,8,8, ......

EXAMPLE INDICATOR CONFIGURATIONS

[Indicator Types]

Indicator1=Accu-Weigh SEP 12K,13,2,c,1, ,-,,3,c,6,0,,,9,c,1,L,K,,10,c,1,G,N,,11,c,1,M, ,,11,c,1,
,O,,13,a,1,10
Indicator2=Analogic 5316,24,0,,,,,,2,c,9,11,c,9,22,c,1,2,0,,21,x,1,0,8,8,21,x,1,0,2,2,21,x,1,1,0,1,24,a,1,10
Indicator3=Cardinal 738,18,2,c,1, ,-,,3,c,7,0,,,12,c,2,lb,kg,,15,c,1,g,n,,10,c,1,m, ,,10,c,1, ,o,,18,a,1,3
Indicator4=CONDEC UMC1000,14,2,c,1, ,-,,3,c,7,0,,,10,c,1,L,K,,11,c,1,G,N,,12,c,1,M, ,,12,c,1,
,O,,14,a,1,10
Indicator5=CONDEC UMC2000,14,2,c,1, ,-,,3,c,7,0,,,10,c,1,L,K,,11,c,1,G,N,,12,c,1,M, ,,12,c,1,
,O,,14,a,1,10
Indicator6=IQ600,14,2,c,1, ,-,,3,c,7,0,,,10,c,1,L,K,,11,c,1,G,N,,12,c,1,M, ,,12,c,1, ,O,,14,a,1,10
Indicator7=IQ700,14,2,c,1, ,-,,3,c,7,0,,,10,c,1,L,K,,11,c,1,G,N,,12,c,1,M, ,,12,c,1, ,O,,14,a,1,10
Indicator8=WI110,14,3,c,1,+,-,,4,c,6,0,,,11,c,2,lb,kg,,2,c,1,G,N,,0,,,,,,,,,,,,14,a,1,10
Indicator9=WI120,14,3,c,1,+,-,,4,c,6,0,,,11,c,2,lb,kg,,2,c,1,G,N,,0,,,,,,,,,,,,14,a,1,10
Indicator10=Toledo
T8142,17,3,s,1,0,2,2,5,c,6,11,c,6,3,s,1,0,16,16,3,s,1,0,1,1,3,s,1,8,0,8,3,s,1,0,4,4,17,a,1,13