Connection instructions, Leak test – King Kooker Fire Pit User Manual

Page 13

Advertising
background image

connectIon InstructIons

1. Check that your manual valve is set to not allow gas flow. The manual valve should be 90 degrees

to the line of gas flow. See below Figure 1. This is the OFF position.

2. Attach the regulator to the cylinder valve by turning the Type 1 fitting clockwise. Refer to the

assembly diagram for the appliance below.

3. Perform the Leak Test:

4. Before lighting the appliance, check that the venturi tube is free of obstruction and that the orifice

located on the valve is properly threaded into the venturi tube. Both situations must be corrected

if necessary before lighting to prevent flashback.

13

leAK test

Before lighting the appliance, a thorough leak test must be satisfactorily completed using

a non-ammonia soapy water solution (50% non-ammonia soap and 50% water). This is to be

applied with a small brush to all gas joints after the cylinder valve is opened (no more than

1/2 turn). If bubbles are seen, indicating a leak, turn off the cylinder and tighten the leaking

connection until a further leak test shows no leaks.

If tightening the connection does not stop the leak, call Metal Fusion, Inc. (800) 783-3885,

for assistance.

neVer use Hose/reGulAtor Assembly IF leAKInG.

mAnuAl VAlVe
(oFF PosItIon)

tyPe 1

connectIon

non-AdJustAble
Pressure
reGulAtor

20 lb.

lP GAs
cylInder