KISAE HB 800 Home Backup User Manual

Page 10

Advertising
background image

Page 10

In0

AL1

Backup
Disabled

AC output is provided by AC utility when utility is available.
Internal battery is automatically charged by the 2A charger.
Inverter is disabled and no backup power occurs when AC utility
is not available. Audio alarm is enabled and will sound when any
warning or fault occurs.

In0

AL0

Backup &
Alarm
Disabled

Same as “Backup Disabled” mode but with alarm disabled. Audio
alarm will not sound when any warning or fault occurs. The unit
fault protection features remain active and will shut down without
audio warning when fault occurs.

To change unit function:

To enter the feature setting mode, press and hold “Power” and “Select” button together for
about 5 seconds until a beep is sounded. Display will show current

inverter setting as “In0 or

In1

Press and hold “Select” button for 1 second to toggle between the two settings.

Once the desired setting is selected, press and hold “Power” button for 1 second to set the
desired setting and carry on with setting the other features.

Display will show current alarm setting as “AL0 or AL1”.

Press and hold “Select” button for 1 second to toggle between the two settings.

Once the desired setting is selected, press and hold “Power” button for 1 second to set the
desired setting and carry with setting the other features.

Display will show “Fd” factory default setting. If you desire to use the factory setting, press and
hold ‘Power’ and ‘Select’ button together for 5 seconds to exit the setting mode. If you wish to
keep all the previous settings on inverter and alarm, just pr

ess ‘Power” button for 1 second and

pr

ess and hold ‘Power’ and ‘select’ button together for about 5 seconds to exit the feature

setting mode.

Note: Press and hold ‘Power’ and ‘Select’ button together for 5 seconds at any time to exit the

feature setting mode. See feature setting chart below.