KISAE HB 800 Home Backup User Manual

Page 12

Advertising
background image

Page 12













Understanding the Error Code

Error
Code

Condition

Corrective Action

E01

System senses battery voltage is low
and has shutdown.

Recharge battery immediately and restart
unit.

E02

System senses battery voltage is high
and has shutdown.

Check battery voltage or if any external high
voltage DC source is connected to DC Input
Port.

E03

System AC output is overloaded or
short circuited and has shutdown.

Check load connected to AC output. Reduce
load and restart the unit.

E04

System senses high internal
temperature and has shutdown

Turn unit off. Wait for 15 minutes before
restarting. Check if any object is blocking the
ventilation of unit.

E05

System warns battery voltage is low
and will shut down shortly

Recharge battery as soon as possible or
system will shut down shortly.

E06

System warns AC load connected is
close to overload shutdown limit.

Check load connected to AC output. Reduce
load.

E07

System warns of high internal
temperature and will shut down shortly.

Reduce load. Check if any object is blocking
the ventilation of unit.

E08 -

09

Not used

E10

Internal battery is overcharged

Check battery voltage or if any external high
voltage is connected to DC Input Port.












Solid red

“E01-E10”

Error on unit is detected. AC output is
disconnected. See Trouble shooting section.

Full

Automatic

Silent

In1, Al0

Same as “Full Automatic” mode but with audio alarm mute if error occurs. The
unit fault protection features remain active.

Backup

Disable

In0,Al1

Solid
green

“Ful”

AC output is supplied by utility power. Internal
battery is fully charged.

Flashing
green

Battery
capacity in %

AC output is supplied by utility power. Charging
of internal battery by 2A charger is in progress.

Backup

Disable

with Alarm

Disable

In0,Al0

Same as “Backup Disabled” mode but with audio alarm mute. The unit fault
protection features remain active.