5. UNIT OPERATION

WARNING: RISK OF EQUIPMENT DAMAGE

Do not plug surge-

protected power bars into the unit’s 120 VAC outlets. The surge protected

components on the surge-protected power bar may not like the modified sine wave output
generated by the unit.

Do not connect an AC power source such as utility power or a generator to the 120 VAC

outlets.

Do not connect the unit’s AC power input cord to its 120 VAC outlets.


Quick Unit Operation Guide

Turn ON and OFF the 120 VAC and USB when Utility AC is not available.

Press and hold the ‘Power’ button for 1 second until a beep is sounded. Display will show the
measured battery capacity and output power alternatively. Status indicator will turn green. 5V
is available at the USB port and 120 VAC is available at the AC socket.

Press ‘Power’ button to turn unit off to save battery power.

Turn ON and OFF the 120 VAC and USB when Utility AC is available.
When utility is available, the unit will perform like a power bar and the AC output cannot be
disconnected unless the AC plug on the unit is removed and the

‘Power’ button is held for a

second to turn unit off.

Using the USB port
The USB port on the system provides standard 5V 750mA power to power up USB powered
handheld device.

Using the 12V DC port
The 12V DC port on the system provides standard 12V 15A maximum DC current to power up
12V lighter plug type automotive handheld appliance.

AC Load connected to the unit
Although the unit can provide high surge power up to two times the rated output power, some
appliances may still trigger the unit

’s protection system. A higher power system like Home Solar

Kit 1800 (HS 1800-60-00) is required for those appliances.
Some appliances like speed controllers found in some fans and AC chargers for some power tools
may not like the modified sine wave generated by the inverter. Those appliances may not work or
may be damaged if they are connected to the inverter. If you are unsure about powering any
device with the inverter, contact the manufacturer of the appliances.


Unit Mode Setting

Mode

Status

indicator

Display

Condition

Full

Automatic

In1, Al1


(factory

default

setting)

Solid
green

“Ful”

AC output is supplied by utility power. Internal
battery is fully charged.

Flashing
green

Battery
capacity in %

AC output is supplied by utility power. Charging
of internal battery by the 2A charger is in
progress.

Solid
amber

Flash between
Output Power
in kW & battery
capacity in %

AC output power is generated by the inverter
using the internal battery and/or from the
optional KISAE solar panel.

Flashing
amber

Same as
above

Same as above and utility AC power is just
detected and AC output will switch to utility
power within seconds.

Advertising