Configuration – KISAE HB 800 Home Backup User Manual

Page 9

Advertising
background image

Page 9

The red connector is used to connect to the positive terminal of the Home Solar System and the
white connector is used to connect to the negative (ground) terminal of the Home Solar System.

Disconnect Solar Panel from Unit:

Cover the solar panel with an opaque sheet or flip the solar panel with the solar cell facing a

flat ground to minimize the output voltage to zero volts.

Verify the Solar charge indicator is off.

Disconnect the solar cable connector from the DC Input Port of the unit.

4. CONFIGURATION

Please read the following table to fully understand unit settings and desire your own desirable
settings. Unit default setti

ng is “Full Automatic” (In1, Al1).


Understanding of Unit Setting

Inverter

Setting

In0

Inverter is disabled, unit will not provide backup function when utility power is not
available

In1

Inverter is set to standby mode. Unit will provide backup function when utility
power is not available

Alarm

Setting

AL0

Audio alarm sound is disabled. Alarm will not sound when warning and fault occur.

AL1

Audio alarm sound is enabled. Alarm sounds when warning or fault occurs.



Unit Function Setting

Setting

Mode of

Operation

Unit Function

In1

AL1

Full
Automatic
(Factory
default)

AC output is provided by AC utility when utility is available.
Internal battery is automatically charged by the 2A charger. AC
output will automatically switch to inverter mode power by the
internal battery when utility is not available. Audio alarm is
enabled and will sound when any warning or fault occurs.

In1

AL0

Full
Automatic
Silent

Same as “Full Automatic” mode but with alarm disabled. Audio
alarm will not sound when any warning or fault occurs. The unit
fault protection features remain active and will shut down without
audio warning when fault occurs.