Table 2 - SERIAL NODE ADAPTER + LECU4012-00
PLC I/O - NPB MODE (DIPSWITCH SW2-1 ON)
BTW
WORD MODULE
CONFIGURATION
0
1
2
3
4
5
MicroPak #1
MicroPak #1
MicroPak #1
----
Atomizer 1
----
High Voltage Setpoint (Value of 0-100 corresponds to 0-100 KV)
Current Limit Setpoint:
HP404 Cascade: 0-250 corresponds to 0-250 µA
RP1000 Cascade: 0-1000 corresponds to 0-1000 µA
Di/dt Setpoint (Value of 0-9 corresponds to max. to min. sensitivity)
(Not Used)
Speed Setpoint:
Liquid: 0-50 corresponds to 0-50 krpm
Powder: 0-250 corresponds to 0-25 krpm
(Not Used)
BLOCK TRANSFER WRITES
BTW
WORD MODULE
CONFIGURATION
0
1
2
3
4
5
6
MicroPak
MicroPak
MicroPak
Atomizer 1
Atomizer 1
Atomizer 1
----
High Voltage Feedback (Value of 0-100 corresponds to 0-100 KV)
Current Feedback:
HP404 Cascade: 0-250 corresponds to 0-250 µA
RP1000 Cascade: 0-1000 corresponds to 0-1000 µA
MicroPak Status Word *
Atomizer Status Word **
Atomizer Drive Pressure (Value of 0-60 corresponds to 0-60 psi)
Speed Feedback:
Liquid: (Value of 0-50 corresponds to 0-50 krpm)
Powder: (Value of 0-250 corresponds to 0-25 krpm)
(Not Used)
BLOCK TRANSFER READS
Serial Node Adapter/Serial Node Adapter + - Operation
Ransburg
16