Ransburg – Ransburg Serial Node Adapter LECU4002_78553 User Manual

Page 20

Advertising
background image

Table 2 - SERIAL NODE ADAPTER + LECU4012-00

PLC I/O - NPB MODE (DIPSWITCH SW2-1 ON)

BTW

WORD MODULE

CONFIGURATION

0

1

2

3

4

5

MicroPak #1

MicroPak #1

MicroPak #1

----

Atomizer 1

----

High Voltage Setpoint (Value of 0-100 corresponds to 0-100 KV)

Current Limit Setpoint:

HP404 Cascade: 0-250 corresponds to 0-250 µA

RP1000 Cascade: 0-1000 corresponds to 0-1000 µA

Di/dt Setpoint (Value of 0-9 corresponds to max. to min. sensitivity)

(Not Used)

Speed Setpoint:

Liquid: 0-50 corresponds to 0-50 krpm

Powder: 0-250 corresponds to 0-25 krpm

(Not Used)

BLOCK TRANSFER WRITES

BTW

WORD MODULE

CONFIGURATION

0

1

2

3

4

5

6

MicroPak

MicroPak

MicroPak

Atomizer 1

Atomizer 1

Atomizer 1

----

High Voltage Feedback (Value of 0-100 corresponds to 0-100 KV)

Current Feedback:

HP404 Cascade: 0-250 corresponds to 0-250 µA

RP1000 Cascade: 0-1000 corresponds to 0-1000 µA

MicroPak Status Word *

Atomizer Status Word **

Atomizer Drive Pressure (Value of 0-60 corresponds to 0-60 psi)

Speed Feedback:

Liquid: (Value of 0-50 corresponds to 0-50 krpm)

Powder: (Value of 0-250 corresponds to 0-25 krpm)

(Not Used)

BLOCK TRANSFER READS

Serial Node Adapter/Serial Node Adapter + - Operation

Ransburg

16

LN-9238-02.3