Table 3 - Node Adapter + LECU4012-00

PLC I/O - Flex Mode (Dipswitch SW2-1 and SW2-5 On) (Cont.)

BTW

WORD MODULE

BTR BLOCK CONFIGURATION

0

1

2

3

4

5

6

7

8

9

X

X

X

X

X

X

X

X

X

Motherboard 0

Motherboard 1

Motherboard 2

Motherboard 3

MicroPak

MicroPak

MicroPak

SerAT1 **

SerAT 1

SerAT 1

----

SerAN 1

SerAN 1

----

SerAN (All)

AirTronic 1

AirTronic 1

AirTronic 1

----

Hardware Configuration and Status Bits

Hardware Configuration and Status Bits

Hardware Configuration and Status Bits

Hardware Configuration and Status Bits

High Voltage Feedback (Value of 0-100 corresponds to 0-100 KV)

Current Feedback:

HP404 Cascade: 0-250 corresponds to 0-250 µA

RP1000 Cascade: 0-1000 corresponds to 0-1000 µA

MicroPak Status Word

Atomizer Status Word

Atomizer Drive Pressure (Value of 0-60 corresponds to 0-60 psi)

Speed Feedback:

Liquid: (Value of 0-50 corresponds to 0-50 krpm)

Powder: (Value of 0-250 corresponds to 0-25 krpm)

(Additional Serial Atomizer Modules)

Channel 1 Pressure Out

Channel 2 Pressure Out

(Additional Serial Analog Modules

Analog Status Word

Channel 1 Actual Flow

Channel 2 Actual Flow

Input Air Line Pressure and Status

(Additional AirTronic Modules)

BLOCK TRANSFER READS