Ransburg – Ransburg Serial Node Adapter LECU4002_78553 User Manual
Page 24
AIRTRONICS FLOW TOLERANCE WORD DEFINITION
BIT
DEFINITION
00-03
04-07
08-11
12-15
CH 1 Low Flow Tolerance, (0-15 equals 0-30% of setpoint)
CH 1 High Flow Tolerance, (0-15 equals 0-30% of setpoint)
CH 2 Low Flow Tolerance, (0-15 equals 0-30% of setpoint)
CH 2 High Flow Tolerance, (0-15 equals 0-30% of setpoint)
Table 3 - Node Adapter + LECU4012-00
PLC I/O - Flex Mode (Dipswitch SW2-1 and SW2-5 On) (Cont.)
BLOCK TRANSFER READ - MOTHERBOARD 0 CONFIGURATION
BIT
DEFINITION
00
01
02-03
04-07
08-11
12-15
BTW word 0 does not agree with Motherboard 0 Hardware Configuration
Serial Node Adapter is in Override Mode
(Not Used)
Motherboard 0, Slot 2 Module Type
Motherboard 0, Slot 1 Module Type
Motherboard 0, Slot 0 Module Type
BLOCK TRANSFER READ - MOTHERBOARD 1 CONFIGURATION
BIT
DEFINITION
00
01
02-03
04-07
08-11
12-15
BTW word 1 does not agree with Motherboard 1 hardware configuration
Serial Node Adapter is in Override Mode.
(Not Used)
Motherboard 1, Slot 2 Module Type
Motherboard 1, Slot 1 Module Type
Motherboard 1, Slot 0 Module Type
Serial Node Adapter/Serial Node Adapter + - Operation
Ransburg
20
LN-9238-02.3