1. Ensure that the rated line voltage and supply

voltage are the same:

115 VAC at 13 AMPS or

230 VAC at 6.5 AMPS

2. The filter heater system should be protected

by appropriate external fusing (115V-16 amp,

230V-8 amp).

3. Ensure that the power connector plug is secured

with a fixing screw prior to operation.

4. Rotate the temperature control knob on the

side of the unit fully counterclockwise to the

‘minimum’ setting.

5. Once the compressed air line has been turned on

and is flowing, provide power to the filter heater

system by plugging the unit into rated outlet.

Do

not exceed the maximum operating pressure

of 230 psi (16 bar).

6. Rotate the control knob clockwise to increase

the air temperature and counterclockwise to

decrease the temperature. The temperature

control knob should be altered gradually to allow

temperature stabilization to take place.

Always

decrease the temperature to the minimum

temperature before unplugging unit.

†

The unit you have purchased is capable of

heating the flow of compressed air to 150°F

( 120°C) maximum. It is essential that all pip-

ing and equipment downstream is suitable for

this temperature. Maximum temperature tol-

erance of flexible air hoses varies significant-

ly, therefore, if in doubt, contact the supplier.

†

The unit must not be exposed to a con-

ducted electrical disturbance greater than a

frequency of 15MHz. The unit may show evi-

dence of a temperature decrease.

There are no serviceable components in the heater

assembly or its associated control electronics. If

a fault or damage occurs to the unit, replacement

spare parts are available.

NOTE

†

Start at miminum temperature set-

ting. Turn air on to the device, then turn

unit up to desired temperature. If you

see condensation on the applicator,

adjust the temperature knob to increase

the temperature.

OPERATION

C A U T I O N

!

†

The heater outlet port area and outlet

pipework will become hot when in use –

avoid personal contact.

†

Serious personal injury can result if these

instructions are not followed.

†

Do not attempt to remove any item on

the heater while it is under pressure.

†

Do not operate if there is a leak in the

filter heater system, immediately take unit

out of service and repair leak.

†

Do not operate above the maximum

working pressure 230 psig (16 bar) at maxi-

mum operating temperature 150°F (120°C).

†

Variable outlet temperature up to 150°F

(120°C) is dependent upon the inlet tem-

perature and air flow rate.

W A R N I N G

!

W A R N I N G

!

†

Heater is hot and should not be touched.