Introduction, Description, Specifications – Ransburg Air Line and Filter Heater A13230 User Manual

Page 8: Ransburg, Air line heater / filter heater - introduction, Supply 115 volt ac, Supply 230 volt ac

Advertising
background image

INTRODUCTION

Air Line Heater / Filter Heater - Introduction

Ransburg

LN-9811-14.1

6

Frequency:

50/60Hz

Power Rating:

1.5 kW

Max. Working

Pressure:

230 psig (16 bar)

Controlled Output

Range:

68° to 150°

(20° C to 65° C)

Minimum Inlet

Temperature:

-4°F (-20°C)

Max Outlet Temp:

248° F, 120° C

Current Draw:

13.0 A

Recommended Fuse:

16 A

SPECIFICATIONS

Supply 115 Volt AC

Frequency:

50/60Hz

Power Rating:

1.5 kW

Max. Working

Pressure:

230 psig (16 bar)

Controlled Output

Range:

68° to 150°

(20° C to 65° C)

Minimum Inlet

Temperature:

-4°F -20°C

Max Outlet Temp:

248° F, 120° C

Current Draw:

6.5 A

Recommended Fuse:

8 A

Supply 230 Volt AC

Ambient temperature, on high-speed applicators,

in automated finishing systems, is hard to maintain

due to the expansion of pressurized air, which re-

sults in condensation. The Ransburg Air Heater/

Filter Heater is designed to reduce, or eliminate,

condensation that may form in or on Air Turbines,

reducing high voltage trip-outs and rejected parts.

Air is heated through a simple process; air enters

through the filter, passes through a Manifold and

Volume Booster before entering the air heater and

exits out to the applicator.

DESCRIPTION

†

This unit is not intended for use within the

hazardous area, (Class 1, Div 1, or Zone 1).

W A R N I N G

!

Advertising