Air Line Heater / Filter Heater - Safety

Ransburg

LN-9811-14.1

2

Spray Area

AREA

Tells where hazards

may occur.

HAZARD

Tells what the hazard is.

SAFEGUARDS

Tells how to avoid the hazard.

Fire Hazard

Improper or inadequate oper-

ation and maintenance proce-

dures will cause a fire hazard.

Protection against inadvertent

arcing that is capable of causing

fire or explosion is lost if any

safety interlocks are disabled

during operation. Frequent pow-

er supply shutdown indicates a

problem in the system requiring

correction.

Fire extinguishing equipment must be present in

the spray area and tested periodically.

Spray areas must be kept clean to prevent the

accumulation of combustible residues.

Smoking must never be allowed in the spray area.

The high voltage supplied to the atomizer must

be turned off prior to cleaning, flushing or main-

tenance.
When using solvents for cleaning:

Those used for equipment flushing should

have flash points equal to or higher than

those of the coating material.

Those solvents used for cleaning must have a

flash point at minimum of 5

o

C (9

o

F) greater than

the ambient temperature. It is the end users

responsibility to insure this condition is met.).

Spray booth ventilation must be kept at the rates

required by NFPA-33, OSHA, country, and local

codes. In addition, ventilation must be main-

tained during cleaning operations using flam-

mable or combustible solvents.

Electrostatic arcing must be prevented. Safe

sparking distance must be maintained between

the parts being coated and the applicator. A dis-

tance of 1 inch for every 10KV of output voltage

is required at all times.

Test only in areas free of combustible material.

Testing may require high voltage to be on, but

only as instructed.

Non-factory replacement parts or unauthorized

equipment modifications may cause fire or injury.

If used, the key switch bypass is intended for use

only during setup operations. Production should

never be done with safety interlocks disabled.

Never use equipment intended for use in water-

borne installations to spray solvent based materials.

The paint process and equipment should be

set up and operated in accordance with NFPA-

33, NEC, OSHA, local, country, and European

Health and Safety Norms.