9060 Cascade Low Voltage Controller - Installation

19

CP-13-07.2

Some codes may require the interlock

wiring to be run in conduit. In this case,
shielded cable is not necessary, but the
conductors used should still meet the rat-
ing specified above.

N O T E

and 105°C and its conductors should be
0.8mm

2

(18 AWG) minimum. Secure the

cable to the interlock connector as de-
scribed in “I/O Connections” in the
“Installation” section of this manual so that
the shield of the cable is connected to the
chassis of the enclosure.

5. Replace the top cover, secure the screws,

replace the fuses, and reconnect the AC
source.

The interlock contacts (supplied by us-

er) should be rated for at least 1 amp at
240 VAC.

N O T E

Description

DC

AC

Max. Switching Capacity

60W

62.5VA

Max. Operating Voltage

125VDC 125VAC

Max. Operating Current

2A

2A

MAXIMUM CONTACT RATINGS

The Controller MUST be OFF when the

applicator is removed or reinstalled.

!

W A R N I N G

RELAY CONTACT
OUTPUTS


A set of relay contacts for high voltage (CR1)
and fault (CR2) conditions is provided at 2TB-2
and 2TB-4 (See Figure 8). One end of these
relay contacts are connected together and also
connected to a source input terminal 2TB-3
(See Figure 11). When a source voltage is
present at 2TB-1 and either the high voltage is
on or a fault condition occurs, the source
voltage will become available at the output end
of the corresponding contact. Maximum
contact ratings are as follows:

When wiring to 2TB, use a shielded cable and
route the wiring through the standard I/O
connector as described in the “I/O Connectors”
section of this manual.

An internal 24 VDC source voltage is

available at 2TB-1. Using a jumper wire,
this voltage may be connected to 2TB-3
to be used as the source voltage for the
relay contact outputs. In this case, the
total current sourced should not exceed 1
amp.

N O T E

The total resistance of the series inter-

locks between L2 and L3 should be less
than 300 Ω.

N O T E

LOW VOLTAGE CABLE

Insert the connection control unit end of the
low voltage cable into the controller. Make
sure that the male notch on the low voltage
cable lines up with the female notch on the
controller, push in (by hand) as far as it will go,
then tighten the nut. Use the same procedure
to connect the low voltage cable to an external
cascade unit. Refer to Figure 12.

Connection-Cascade End

Connection-Control Unit End

Figure 12: Low Voltage Cable