9060 Cascade Low Voltage Controller - Maintenance

29

CP-13-07.2

Fault

Description

Solution

Voltage Cable
Fault (UC)

The Voltage Feedback Fault indi-
cates the cascade drive signal is
not present. It typically occurs
when high voltage is triggered.

1. Replace the barrel assembly and re-test.

2. Replace the main pc board and re-test.

Boot Fault (bF)

The Boot Fault indicates that an
active trigger signal was detected
during the start-up sequence.

1. Turn off the voltage controller.

2. Ensure that the gun trigger is not pressed

so the remote trigger input signal is not ac-
tive.

3. Turn on the voltage controller to verify that

a trigger signal is not present and that the
unit enters the ‘ready’ state.

4. Send the voltage controller in for repair or

contact technical support.