Maintenance, Troubleshooting guide fault troubleshooting guide, 9060 cascade low voltage controller - maintenance – Ransburg 9060 LV Cascade Controller 80131-XXX User Manual

Page 32

Advertising
background image

9060 Cascade Low Voltage Controller - Maintenance

27

CP-13-07.2

General Problem Possible Cause

Solution

Blank Display

1. No power

2. Blown fuse

1. Check the power connections and verify

they are fully connected and power is avail-
able. Power cycle the unit off and back on.

2. Check Fuses and replace if blown using

the replacement fuses inside the lid of the
unit.

MAINTENANCE


TROUBLESHOOTING GUIDE

FAULT TROUBLESHOOTING GUIDE

Before troubleshooting gun and control unit problems, flush the gun with solvent and purge

with air. Some of the tests will require high voltage to be applied to the gun, so the gun must
be empty of paint and solvent.

!

W A R N I N G

Fault

Description

Solution

Cable Fault (CF)

The Cable Fault indicates the con-
trol unit does not detect a high
voltage section on the end of the
cable. The fault typically occurs at
a high voltage trigger.

1. Check for a loose connection on the low

voltage cable and tighten if necessary.
Insure both connectors are secure and re-
test for CF fault.

2. Replace low voltage cable and re-test.

3. Send unit in for repair.