Maintenance – Robinair 34788-H Recovery, Recycling, Recharging Unit User Manual

Page 19

Advertising
background image

17

560826 Rev. D, August 23, 2013

Maintenance

General Maintenance

1. On a regular basis, wipe off the unit using a

clean cloth to remove grease and dirt.

2 . Periodically check internal components for

leaks; over time, fittings can loosen as the unit
is moved. Open the door panel, and trace lines
using a leak detector. Check connections on
the back of the unit. Tighten any loose fittings or
connections you may find.

Electrical Protection

The unit is equipped with a 15 amp circuit breaker
on the back panel. See Figure 12. If the breaker
trips, its button will pop out. A tripped circuit
breaker will cause the unit to lose all power.
Press the circuit breaker button to reset.

Manually Fill the
Internal Storage Vessel (ISV)

This menu item is used to transfer refrigerant from
a source tank to the internal storage vessel.
Note: If a refrigerant source tank remains
connected to the unit during normal operation, the
correct amount of refrigerant will be automatically
maintained in the ISV. The ISV may be manually
refilled, if necessary.
1. Press Menu, and use arrow keys to select

MANUAL REFILL. Press START / YES. The
unit displays

CONNECT SOURCE TANK

START TO BEGIN

2. Connect the fill hose to a full source tank, and

open the source tank valve.

3. Install the source tank, and secure it to the unit

with the source tank strap in such a way that
liquid refrigerant is supplied to the connection.

4. Press START / YES to begin. The display

shows

TANK FILL IN PROGRESS

TRANSFER XX LBS

5. The unit automatically stops when the preset

tank fill level is reached, or press STOP / NO to
exit.

Figure 13

Side View

Fill Hose

Power

Cord

Source

Tank

Strap

Low- and

High-Side

Hoses

Circuit

Breaker

Figure 12

Back View

Advertising