4

Menu Functions

1. Press the MENU button on the keypad.
2. Press the UP or DOWN arrow key to scroll

through the menu choices shown on the

second line of the display :

SELECT LANGUAGE

VERSION X.XX

SELECT UNITS

MAINTAIN VACUUM OIL

MAINTAIN FILTER

REFRIG MANAGEMENT

MANUAL REFILL

ADJUST TANK FILL LVL

CALIBRATION CHECK

SELECT BEEPER TONE

SERVICE MENU

HOSE FLUSH

DISPLAY TANK INFO

SYSTEM FLUSH
3. Press START / YES to make a choice

from the menu. Press STOP / NO to pause

during any process, and STOP / NO a

second time to exit a process.

Introduction

Select Language

Operator may choose to have prompts displayed in one of three
languages: English, Spanish, or French.

Version X .XX

Displays the revision level of the software in the unit.

Select Units

The operator may choose to have test results displayed in
Imperial (lb.), Imperial (lb. and oz.), or Metric (kg).

Maintain Vacuum Oil

For maximum vacuum pump performance, change vacuum
pump oil after every 10 hours of operation. This menu item

Arrow

Keys

Start / Yes

Button

Stop / No

Button

Menu

Button

displays how long the vacuum pump has operated since the
last oil change, and allows the user to reset the value once an
oil change is complete. Refer to the instructions outlined in the
Maintenance section under Change Vacuum Pump Oil .

Maintain Filter

The filter-drier removes acid, particulates, and moisture
from the refrigerant. To meet SAE J-2788 requirements,
it is mandatory to replace the filter-drier after 150 lbs.
(68 kg) of refrigerant has been filtered. This menu item shows
how much refrigerant has been filtered since the last filter
change, and allows the user to reset the value once a filter
change is complete. A code, which appears on the filter, must
be entered into the unit to ensure compliance with SAE J-2788.
Refer to instructions outlined in the Maintenance section under
Replace the Filter-Drier .

Refrig Management

Displays the amount of refrigerant recovered, charged, and
replenished (for the life of the unit), and filtered (since the last
filter change).

Manual Refill

Use to transfer refrigerant from the source tank to the internal
storage vessel (ISV). Refer to instructions outlined in the
Maintenance section under Manually Fill the ISV .

Adjust Tank Fill LVL

When connected to a refrigerant source, the unit maintains
a pre-set amount of refrigerant in the internal storage vessel
(default is 15 lbs.). This value may be adjusted up or down
to suit the user’s needs. Refer to instructions outlined in the
Maintenance section under Adjust Tank Fill Level .

Calibration Check

Use to verify internal scale calibration. Refer to instructions in
Maintenance section under Scale Calibration Check .

Select Beeper Tone

Select one of two tones for an alert signal, or mute the signal
completely.

Service Menu

For Robinair service center use only.

Hose Flush

Flushes residual PAG oil from the unit for service of electric
POE oil-based hybrid systems.

Display Tank Info

Displays internal storage vessel (ISV) pressure and temperature.
Use to check the ISV for excessive pressure.

System Flush

When used with the appropriate flush adapter kit, this menu
item allows the A/C system or component to be flushed with
R-134a refrigerant.