Set Tank Fill Level

The operator may either accept the unit’s pre-set
default weight of 15 lbs. (6.8 kg) of refrigerant
stored in the internal storage vessel (ISV),
or change the amount to accommodate the
application.
The unit displays

LEVEL: 15.00 LBS.

ENTER TANK FILL LVL

LIMIT: 4 TO 17 LBS.

PRESS START / YES TO SAVE

1. Press START / YES to accept the default

amount, or use the keypad to enter a desired
amount and press START / YES.

Add Oil to the Vacuum Pump

CAUTION: The vacuum pump is shipped
without oil in the reservoir . Failure to add oil to
the vacuum pump will damage the pump .

The unit displays

ADD 5 OZ OF NEW OIL

TO VACUUM PUMP

START TO CONTINUE

1. Remove the brass plug from the vacuum pump

oil fill port. See Figure 3.

2 . Attach the flexible tube/cap to the oil bottle; pour

only five (5) ounces of vacuum pump oil into
the fill port. Note: You will top off the oil in the
next step as the vacuum pump is running.

3. Press and release the START / YES key. While

the vacuum pump is running, slowly add oil until
the level rises to the center of the reservoir’s
sight glass.

4. Press the STOP / NO key to stop the vacuum

pump, and install the brass plug in the fill port.

5. Press START / YES to continue.

Setup

Sight

Glass

Fill Port

Vacuum Pump

Sight Glass

CAUTION: The unit is programmed

to run the setup procedure as outlined
here . To prevent personal injury, do
NOT operate the unit at any other
time without the brass plug installed,
because the vacuum pump is
pressurized during normal operation .

Fill Port

Figure 3