background image

PN# 500-23300

Page 4

Rev. B, 07/13

Component Label

Component Name

Selection

Position

SW3

(M370 has a

2-position DIP)

DIP Switch SW3.1:
LED Enable
Position 1 setting of the
DIP switch enables or
disables the display of
the LED for lock status.

ON = LED ENABLED

Position 1 ON (default)

OFF = LED DISABLED
(default setting)

Position 1 OFF

SW3

DIP Switch SW3.2:
LED Color Select
Position 2 setting of the
DIP switch controls the
color of the LED
output. Output options
are red or green.

ON = SECURE = RED

Position 2 ON

OFF = SECURE = GREEN
(default setting)

Position 2 OFF (default)

SW3

(Auto Relock Timer

available on M380

models only)

DIP Switch SW3.3,
SW3.4 and SW3.5:
Auto Relock Timer
Enable and Delay
Selection
The Auto Relock Delay
Timer is disabled by
default. The delay can
be enabled by setting
the position 3 switch of
SW3 to ON, and then
selecting a time delay
with Position 4 and
Position 5 of SW3.

DISABLE Delay Timer

Position 3 OFF (default)

ENABLE Delay Timer

Position 3 ON

5 second delay

Position 4 OFF
Position 5 OFF

10 second delay

Position 4 OFF

Position 5 ON

20 second delay

Position 4 ON

Position 5 OFF

30 second delay

Position 4 ON
Position 5 ON

JP3

(available on M380

models only)

Jumper 3:
BondSTAT
Mode Select
A 3-pin jumper that
controls the output
setting for the
BondSTAT in Terminal
Block J1 Position 7 & 8.

(NC) Normally Closed
Circuit Closed when Bond is
secure (default setting)

(NO) Normally Open
Circuit Open when Bond is
secure

JP4

(available on M380

models only)

Jumper 4:
Door Position
Mode Select
A 3-pin jumper that
controls the output
setting for the Door
Position Switch (DPS)
in Terminal Block J1
Position 1 & 2.

(NC) Normally Closed
Circuit Closed when Door is
Closed (default setting)

(NO) Normally Open
Circuit Open when Door is
Closed

Advertising