Document configuration settings – Securitron M380BD User Manual

Page 5

Advertising
background image

PN# 500-23300

Page 5

Rev. B, 07/13

J1 (M370)

Terminal Block 1

(M370 has a 4-position terminal block)

Position 1 & 2:
Input Power

Terminal positions 1 & 2 provide a connection point for
positive (+) and negative (-) 12 and 24 VDC power
connection.
Position 1 = (+) Positive
Position 2 = (-) Negative

Position 3 & 4:
Tamper Indication

Terminal positions 3 & 4 of the terminal block provide
connection for tamper sensing. Signal continuity is
disrupted whenever the cover is removed.

J1 (M380)

Terminal Block 1

(M380 has an 8-position terminal block)

Position 1 & 2:
Door Position Switch

Terminal positions 1 & 2 provide a set of contacts of which
state change is determined by Jumper 4 (JP4) based on
the strike plate’s proximity to the lock face.

Position 3 & 4:
Input Power

Terminal positions 3 & 4 provide a connection point for
positive (+) and negative (-) 12 and 24 VDC power
connection.
Position 3 = (+) Positive
Position 4 = (-) Negative

Position 5 & 6:
Tamper Indication

Terminal positions 5 & 6 provide connection for tamper
sensing. Signal continuity is disrupted whenever the cover
is removed.

Position 7 & 8:
BondSTAT

Terminal positions 7 & 8 provide a set of contacts of which
state change is determined by Jumper 3 (JP3) based on
the strike plate’s magnetic bond to the lock face under
power.

3.

Document Configuration Settings

The Board Settings are now complete. Copy your settings onto the adhesive-backed Circuit Board Settings label
enclosed with the mounting hardware packet.

Note: The example shows the
Default settings. Your settings may
vary, based on your checklist.

NO = Normally Open
NC = Normally Closed

Important! Complete the label and affix to the inside cover of your Magnalock

®

This information will be needed if the lock needs to be serviced, replaced or inspected.

M370/M380 Settings

www.securitron.com
1-800-624.5625

ON=ENABLED

ON=RED

1-2=NC
1-2=NC

ON=ENABLED

OFF=DISABLED

OFF=GREEN

2-3=NO
2-3=NO

OFF=DISABLED

5 10 20 30

* available on M380BD models only

Advertising