program mode and you can attempt to re-enter your user code. If you continuously get the
error signal, refer to the troubleshooting section which explains all the possible reasons for a
code not being accepted.


After you’ve completed your entries, test your User and Program Codes by entering
them
. The User code should open the door. Entering the Program Code followed by the “E”
key should cause the yellow LED to flash rapidly (program mode). Exit the program mode by
hitting the “E” key. Below we show a step by step summary of programming the two codes.

o Power up unit; confirm 5 second yellow LED (after any key is pressed).
o Press the “PRGM” button on the CPU board for one second.
o Confirm rapid flashing yellow LED.
o Within 30 seconds of pressing PRGM button, enter prefix 0-0 followed immediately

by a 5-7 digit Program Code.

o End your entry with “E” key or wait 5 seconds.
o Note two (2) red LED flashes for confirmation, note rapid yellow flashing LED

returns.

o Enter prefix 0-1 followed immediately by a 2-7 digit User code.
o End your entry with “E” key or wait 5 seconds.
o Note two (2) red LED flashes for confirmation, note rapid yellow flashing LED

returns.

o Press “E” key to terminate program mode or wait 30 seconds.
o Re-enter User code (door should open).
o Re-enter Program Code followed by the “E” key (yellow LED should rapidly flash);

terminate with “E” key.


6.2.1. Changing The User and Program Code from the Keypad

This is the day to day procedure that should be taught to the end user. Normally the
end user will not access the CPU board. Everything should be done from the keypad. To

change the User code:

o Enter Program Code, followed by the “E” key, note rapid yellow flashing LED

(program mode).

o Enter prefix 0-1 followed immediately by a new 2-7 digit User code.
o End your entry with “E” key or wait 5 seconds.
o Note two red LED flashes for confirmation, note rapid yellow flashing LED returns.
o Press “E” key to terminate program mode or wait 30 seconds.
o Re-enter new User code (door should open).

The Program Code should need changing much less often. To do it:

o Enter old Program Code followed by the “E” key, note rapid yellow flashing LED

(program mode).

o Enter prefix 0-0 followed immediately by a 5-7 digit new Program Code.
o End your entry with “E” key or wait 5 seconds.
o Note two red LED flashes for confirmation, note rapid yellow flashing LED returns.
o Press “E” key to terminate program mode or wait 30 seconds.
o Re-enter new Program Code followed by the “E” key (to test it), note rapid yellow

flashing LED returns.

o Press “E” key to terminate program mode or wait 30 seconds.

The logic behind this procedure is as follows. All programming for the SABL starts with
putting the unit into program mode (except entering the single Hard Code). The unit is
put into program mode by either pressing the “PRGM” button on the CPU board or
entering a valid Program Code. When you enter a Program Code, however, you have to

terminate the sequence with the “E” key. This is for a little extra security and
ensures that the program mode is not accessed by mistake. The prefix 0-0 causes the
code which follows to be stored as the Program Code. The prefix 0-1 causes the code to
be stored as a user code.