Securitron SABL INSTALLATION User Manual

Page 5

Advertising
background image

PN#

500-19700

Page

5

Rev. C, 8/07

SABL Installation:


1. Ensure door has been prepared as described in the previous section.

2. Unpack the SABL from its packaging box.
3. Using a 3/32” hex (Allen) wrench remove the 8-32 UNC X 1/4” long hex socket pan

head screw (Item #7 of Figure 1) and remove the SABL battery access cover
(Item #3) from the battery and electronics chassis (Item #2). Set the screw,
cover and chassis aside for later use.

4. Unpack and disassemble the lockset.

a. Remove the lockset from its packaging box.
b. Using the handle removal tool provided, remove the inside handle of the lockset

(Item #10).

c. Remove the rose scalp (Item #11) from the inside rose of the lockset.
d. Using a screwdriver, remove the two (2) screws (Item #12) holding the inside

and outside rose assemblies together.


Lockset door thickness adjustment:

The lockset as provided is pre-adjusted for a 1-3/4” [44mm] thick door. If adjustment to

accommodate a different door thickness is required, please determine the style of lockset
(“A” or “B”) and refer to the accompanying instructions and illustrations to adjust the
lockset as follows:


A. Using a screwdriver, remove the two (2) screws holding the lock body to the

outside rose as shown in Figure 5.

B. Remove the lock body from the outside rose assembly.
C. Extract the two (2) alignment pins from out of the lock body as shown in

Figure 5.

D. Adjust the lockset for proper door thickness as described for Style “A” or

“B” – Step E.

Figure 5

Style “A” (lockset with threaded adjustment for door thickness):


E. Rotate outside rose placement plate along the threaded body until the

required distance is achieved as shown in Figure 6.

9/32" (7.1mm) for 1-3/4" (44mm) Door
3/16" (4.7mm) for 2" (51mm) Door
1/16" (1.6mm) for 2-1/4" (57mm) Door

Figure 6

(2) Alignment Pins

(2) Screws

Rose Placement

Plate (Threaded)