20.Install inside rose scalp (Item #11) over the inside rose assembly (Item #13).
21.Install the inside lever handle (Item #10) over the end of the inside rose assembly

(Item #13) and firmly snap the handle into place.

22.Using a screwdriver, tighten the two (2) screws (Item #9) holding the latch

assembly (latchbolt) (Item #8) in place.

23.Test the handle actuation. If necessary, loosen screws as required, and adjust the

assembly so that it functions smoothly.

24.Remove battery inhibitor tab from between the battery and terminal. (The unit will

beep once to indicate power is available). At this point the unit should be
programmed in accordance with Section 6.

25.After programming has been completed, install the SABL battery access cover

(Item #3) over the battery power chassis by hooking the top tab of the cover onto
the receptacle flange of the chassis, then using the 3/32” hex (Allen) wrench install

the 8-32 X 1/4” long hex socket pan head captive screw (Item #7) at the base of
the cover. Note: To obtain a proper fit of the access cover to the power chassis,
the top receptacle flange of the chassis may be adjusted by slightly bending toward
the door face (to tighten fit) or away from the door face (to loosen fit).

5.3. Strike Plate Installation
Note:
A strike plate has been provided and is considered necessary for wear protection of
the door frame and for the proper function of the lock mechanism.

5.3.1. Installation of Strike Plate on Door Frame
The following illustration (Figure 11) is an exploded view of the assembly of a strike plate
onto a door frame:

17

16

(Reference)

Cut Away View of

Prepped Door Frame

Figure 11

Strike Plate Installation:

1. Place Strike Plate (Item #16) into position on prepped door frame.
2. Using screwdriver secure the strike plate in place on the door frame using the two

(2) screws provided (Item #17).