Warning, Caution – Alliance Laundry Systems WF150 User Manual

Page 32

Advertising
background image

32

4

Electrical Installation

Important
Electrical ratings are subject to changes. Refer to serial plate decal for electrical ratings information

specific to your machine.

WARNING

Hazardous Voltage. Can cause shock, burn or cause

death. Allow machine power to remain off for two minutes

prior to working in and around AC inverter drive.

WARNING

Hazardous Voltage. Can cause shock, burn or death.

Verify that a ground wire from a proven earth ground is

connected to the lug near the input power block on this

machine.

The AC inverter drive requires a clean power supply free from voltage spikes and surges. If a

transformer or generator is connected to the building's power supply, always install line reactors

before the terminal block connections to the machine. A voltage monitor should be used to check

incoming power. The customer’s local power company may provide such a monitor.

If input voltage measures above 240V for a 220V drive or above 480V for a 400V drive, ask the

power company to lower the voltage. As an alternative, a step-down transformer kit is available

from the distributor.

The AC drive provides overload protection for the drive motor. However, a separate single or

three-phase circuit breaker must be installed for complete electrical overload protection. This

prevents damage to the motor by disconnecting all legs if one should be lost accidentally. Check

the data plate on the back of the washer-extractor or consult Table 3 through 7 for circuit breaker

requirements.

IMPORTANT: Do NOT use fuses in place of a circuit breaker.
For installation in the United States or Canada, branch circuit protection must be provided

according to National and Local Codes. The branch circuit breaker must be of the inverse time or

instantaneous trip type at the values given in the technical specifications for each machine.

Use a circuit breaker of the minimal type of 10kA interrupt current.

CAUTION

Do not use a voltage or phase converter on any variable speed machine.

The washer-extractor should be connected to an individual branch circuit not shared with lighting or

another electrical device.

- In accordance with legal regulations, every machine must be protected with an earth leakage

circuit breaker of 30mA.

- The earth leakage circuit breaker, which one uses, must be of the type SI.
- For countries outside the European Community, the usual safety instructions must be observed.

Advertising
This manual is related to the following products: