Warning, Caution – Alliance Laundry Systems WF150 User Manual

Page 41

Advertising
background image

Label 5

Label 6

4

41

The liquid soap connection consists of 8 connections for liquid soap

(See Label 5).
The central opening is used for ventilation.

Liquid soap connection (option)

Connection of the liquid soap hoses

WARNING

Dangerous Chemicals. May damage eyes and skin. Wear eye and

hand protection when handling chemicals; always avoid direct

contact with raw chemicals. Read the manufacturer’s directions for

accidental contact before handling chemicals. Ensure an eye-rinse

facility and an emergency shower are within easy reach. Check at

regular intervals for chemical leaks.

CAUTION

Drill out plugs and nipples before making supply hose connection.

Failure to do so can cause buildup of pressure and risk a tubing

rupture.

Electrical connection of the liquid soap pumps

On machines equipped with a liquid soap connection, connect the wires directly on

the print board next to the ground wire connection (option). Connect as indicated on

the wiring diagram.

The two connectors on the right give a tension of 220V ~ (max. 4A) which can

be applied to drive 220V ~ soap pumps. If more than 4A is required, an external

tension will have to be used. 6 connections have been provided, of which one (S6)

can be used to drive a waterproofing pump (e.g. for rain coats, etc.). (See Label 6)

Advertising