Alliance Laundry Systems WF150 User Manual

Page 35

Advertising
background image

4

35

200-240 Volts, 3-Phase, 3-wire + PE, 50 or 60 Hertz Configuration (Named: Q-Voltage or 3-phase X-Voltage):

With supply power of: 200-240 Volts, 3-phase, 3-wire, after connecting the green/yellow PE ground wire, connect one power

wire to each of the terminals at the bottom of the power contactor switch marked: “L1,L2,L3”.

200-240 volts, 1-Phase, 2-wire + PE, 50 Hertz (called 1-phase, 50 Hz X-voltage):

With supply power of: 200-240 Volts, 1-phase, 2-wire, 50Hz, after connecting the green/yellow PE ground wire, connect

the power wire to the “L1” bottom terminal of the power contactor switch and the other wire, identified as the neutral wire,

to the bottom terminal of the auxiliary contactor on the power contactor switch marked: “N”.

200-240 volts, 1-Phase, 2-wire + PE, 60 Hertz (called 1-phase, 60 Hz X-voltage):

With supply power of: 200-240 Volts, 1-phase, 2-wire, 60Hz, after connecting the green/yellow PE ground wire, connect
one power wire to the “L1” and power wire to the “L2” of the bottom terminals of the power contactor switch.

After connection, check the spin direction. The cylinder must spin in the clockwise direction.

A wrong spin direction can damage the motor and can also cause water to spurt from the soap dispenser.

In case of wrong spin direction: switch the terminal clamps of the motor circuit “R” and “S” of the connecting cable or

change the connection at the terminal block switching the L1 and L2 wires.

Advertising
This manual is related to the following products: