Warning – Alliance Laundry Systems WF150 User Manual

Page 39

Advertising
background image

4

39

WARNING

The washer-extractor should be connected to an individual branch

circuit not shared with lighting or other equipment.

4

Electrical Specifications WF305, IWF305, IWF075, CWF305, CWF075

305 liters / 75 pounds

Boiler Fed/Steam Heat

Electric Heat

Code

Voltage

Cycle

Phase

Wire

Full
Load Amps

Recommended Circuit

Breaker (US-market)

AWG/mm2

kW Standard

Heating Elements

Full
Load Amps

Recommended

Circuit Breaker (US-

market)

AWG/mm2

US NON-US

US NON-US

N

440-480 50/60

3

3+PE

6

15

10

14/2.5

6x4 kW

32

50

50

8/10.0

P

380-415 50/60

3

3+N+PE 16

20

20

12/4.0

43

70

70

4/25.0

Q

200-240 50/60

3

3+PE

16

20

20

12/4.0

6x3 kW

60

70

70

4/25.0

X

200-240 50/60

1/3

2/3+PE

16

20

20

12/4.0

N/A N/A

N/A

N/A

Alternative Electric Heat Options

N

440-480 50/60

3

3+PE

3x3 kW +

3x4 kW

36

50

50

8/10.0

P

380-415 50/60

3

3+N+PE

48

70

70

4/25.0

Q

200-240 50/60

3

3+PE

N/A N/A

N/A

N/A

X

200-240 50/60

1/3

2/3+PE

N/A N/A

N/A

N/A

Table 6

Advertising
This manual is related to the following products: